1. Where the equipment comes from
Every item is purchased at retail price with lab funds. We do not accept review samples, loans, or early units from manufacturers. When a product is purchased, the order date and price paid are recorded on its test page. If a manufacturer learns about a test and offers anything in exchange for a change in verdict, we publish the offer.
2. Test protocols
Heater stability
A heater runs in a calibrated volume of water (stated per test, 20 L bench tank) at a stated setpoint. Two independent temperature probes log the water temperature at 1-minute intervals for a minimum 24-hour run. We report: mean deviation from setpoint, maximum overshoot, cycling behaviour, and failure-safety behaviour (what happens when the thermostat is deliberately fouled — heater fully submerged vs. partially). Three runs per unit; all raw logs are published as tables.
UVB output and decay
UVB Index is measured with a Solarmeter 6.5R at a fixed distance and angle (both stated), on a dark bench, meter warmed up per the manual. Each bulb is measured at installation, then re-measured on a fixed monthly schedule for its stated service life and beyond. Bulbs are aged in their real fixture, on their real photoperiod, so decay reflects use — not a storage drawer.
Filter flow
Flow is measured volumetrically: water pumped through the filter returns to a graduated container; three timed runs are averaged. We report actual flow as a percentage of the manufacturer's claimed flow, with the measurement uncertainty (approximately ±5% for this rig) stated on the page.
Incubator temperature curves
Each incubator is loaded with a stated thermal mass (water-filled containers simulating egg clutches) and run for 72 hours at a stated setpoint. Two probes log at 1-minute intervals. We report mean deviation, peak-to-peak swing, and recovery time after a door-opening event.
3. What we deliberately do not test
We do not test with live animals. Every measurement on this site can be made with instruments and water containers. Animal-welfare-sensitive claims (behavioural enrichment, breeding success) are out of scope and will be labelled as out of scope.
4. Uncertainty and error bars
Every test page states the instrument, the calibration status, the measurement uncertainty, and the number of runs. Where a difference between products is smaller than the uncertainty of the measurement, we say so explicitly instead of declaring a winner.
5. Funding and affiliate disclosure
If, in the future, we join affiliate programs (manufacturer-direct programs or retail programs), this page will list every program, and every affiliate link on the site will be visually labelled. The verdicts in the data tables are produced before monetization decisions and are not for sale; if we cannot keep that line, we will shut the site down instead of blurring it.
6. Corrections
If you find a protocol error, a unit error, or a bug in our data tables, tell us and we will correct the page with a dated correction note describing what changed. Corrections are visible history, not silent edits.
7. How to cite this site
Forums, articles and AI answers are welcome to quote the data tables. Please cite the specific page, not the homepage: